A notice board is a board fixed to a wall, used to relay information such as notices or to display work. In schools it is most often found in corridors and classrooms, where the Department for Education's BB 100 sets limits on its width, spacing and cover.[1]
Key points
- BB 100 says school circulation routes will almost certainly be important for relaying information to pupils by notice boards, or used as a display area for pupils' work.[1]
- BB 100 limits notice boards in corridors to 3 m wide, with at least 1 m between boards on the same wall.[1]
- Approved Document B, the fire safety guidance for England, does not use the words "notice board" in volume 2.[2]
- This page found no standard that defines a notice board as a product, so fire evidence comes from the board's materials and how it is fixed, classified under BS EN 13501-1.[2][3]
How it works
A notice board is a surface that holds items, whether by pins, magnets, a transparent cover or a lock. The surface material, the frame and any cover are what a fire assessor looks at, because the guidance for England deals with the surface linings of walls and ceilings, and sets classes for them rather than for furniture or boards by name.[2] For a corridor, that class is B-s3, d2.[2] See Euroclass B.
Types or sizes
Notice boards differ by surface, cover and security, and each has its own entry.
- Open boards, where the surface is exposed for pinning. See classroom display board.
- Glazed boards, with a cover over the surface. See glazed notice board.
- Lockable and tamperproof boards, where access is controlled. See lockable notice board and tamperproof notice board.
The numbers
These come from BB 100, published in March 2014, which predates the 2025 changes to Approved Document B.[1][2]
- Classrooms: notice boards with a surface spread of flame are permitted, but should not extend more than 2.5 m without a break of not less than 0.4 m, and should be away from potential sources of ignition (section 5.2.2.1).[1]
- Dead end corridors: no notice boards unless covered by a suitable material such as glass or polycarbonate.[1]
- Corridors: not more than 3 m wide, at least 1 m between boards on the same wall, and a cover, preferably top hung, in a protected corridor (section 3.1.6).[1]
In schools and SEN settings
BB 100 covers special schools and pupil referral units as well as mainstream schools, and does not set separate display rules for SEN settings.[1] Where a school uses displays as part of how it supports pupils, the fire limits above still apply to the boards themselves.
How to choose
- Ask the school's fire risk assessor or building control which limits apply to the corridor or room in question.
- Ask the supplier for the test evidence for the exact surface, with the full European class and how the sample was fixed.[2][3]
- Be wary of evidence that quotes only a national class. BSI lists BS 476-7:1997 as withdrawn on 4 March 2025, and Approved Document B removed national classes for reaction to fire in amendments effective 2 March 2025.[2][4]
What people get wrong
- Assuming a corridor board can run along a whole wall. BB 100 sets a 3 m maximum width and a 1 m gap.[1]
- Treating "notice board" as a fire rating. It is a product description, and the rating belongs to the tested material and fixing.[2][3]
- Treating BB 100 as current on classes. It dates from March 2014.[1]
FAQ
How big can a school notice board be?
In corridors BB 100 says not more than 3 m wide, with at least 1 m between boards on one wall.[1] In classrooms it limits a run to 2.5 m before a break of at least 0.4 m.[1]
Does a notice board need a fire rating?
BB 100 refers to notice boards with a surface spread of flame, and Approved Document B sets lining classes for corridors and rooms.[1][2] Whether a given board counts as a lining is for building control or the fire risk assessor to decide.
Is a noticeboard the same as a notice board?
Yes, the two spellings describe the same item. This glossary uses "notice board".
Related terms
- Classroom display board
- Glazed notice board
- Lockable notice board
- Tamperproof notice board
- Building Bulletin 100
- Surface spread of flame
See it in our range
Notice boards: ask for the test evidence for the exact board and how it is fixed.
Sources
- Design for fire safety in schools: BB 100. Department for Education (GOV.UK), March 2014. Accessed November 2026.
- Approved Document B (fire safety) volume 2: Buildings other than dwellings, 2019 edition incorporating 2020, 2022, 2025 and 2026 amendments collated with 2029 amendments. Ministry of Housing, Communities and Local Government (GOV.UK), GOV.UK page last updated 16 September 2026. Accessed November 2026.
- BS EN 13501-1:2018 Fire classification of construction products and building elements: Classification using data from reaction to fire tests. BSI Knowledge, published 31 January 2019. Accessed November 2026.
- BS 476-7:1997 Fire tests on building materials and structures: Method of test to determine the classification of the surface spread of flame of products. BSI Knowledge, published 15 January 1997, withdrawn 4 March 2025. Accessed November 2026.