Written by Joanne Mulloy, Acoustic Solutions Specialist & Technical Reviewer
Reviewed by Joe Sutcliffe, Managing Director & Lead Acoustic Surveyor
Presentation Spaces Ltd ·
A classroom display board is a wall-mounted board, usually pinnable, used in classrooms and corridors to show pupils' work, timetables and information. In England, DfE fire guidance for schools allows notice boards with a surface spread of flame rating in classrooms, within limits on length, gaps and position.[1]
Key points
- BB100, the DfE's fire safety guide for schools, permits notice boards with a surface spread of flame rating in classrooms, subject to limits.[1]
- BB93, the DfE's acoustic guide, says a school design needs to allow for ample surfaces for display materials among pupils' other environmental needs.[2]
- BB100 and BB93 are guidance. Whether a display complies in a particular school is decided by that school's fire risk assessment and building control.
- Layout affects readability. The British Dyslexia Association's guide recommends chunking, white space and consistent layouts for written material.[3]
How it works
A display board gives a place to fix work and notices without marking the wall. In a classroom it may be felt, cork or another pinnable surface. The fire guidance is about how much combustible surface is on the wall and where it sits, so the size and the gaps matter as much as the material.[1]
The numbers
BB100 gives limits for notice boards, with the section where each sits.[1]
- Classrooms (section 5.2.2.1): boards with a surface spread of flame rating are permitted, but should not extend more than 2.5 m without a break of at least 0.4 m, and should be away from potential sources of ignition.[1]
- Corridors (section 3.1.6): boards should not be more than 3 m wide, with a gap of at least 1 m between boards on the same wall.[1]
- Protected corridors: boards should be fitted with a cover, preferably top hung so that it cannot be left jutting out into the escape route.[1]
- Dead end corridors: no boards unless covered by a suitable material, for example glass or polycarbonate.[1]
BB100 dates from 2014. Confirm the current requirement with the school's fire risk assessment before fitting a board.
In schools and SEN settings
BB93 places display surfaces among the environmental needs a school design should allow for.[2] For pupils with dyslexia, the BDA guide says no single format works for everyone and that individual preference and the ability to customise are more important than fixed formatting rules.[3] A wall cannot be personalised for every reader, so keep content in short, headed chunks with white space between them. See dyslexia-friendly display and visual timetable.
How to choose
- Check the board's fire rating and the evidence for it against the school's fire risk assessment; see surface spread of flame.
- Plan board lengths and gaps against the BB100 figures before ordering.[1]
- Choose the surface for what will be fixed to it. A felt notice board takes pins, and the notice board entry covers other surfaces.
- Leave room for a working wall if the class uses one.
What people get wrong
- Covering every wall. BB100 limits board length and requires gaps.[1]
- Applying one limit everywhere. BB100 gives different figures for classrooms and corridors, so check which room the board is in.[1]
- Treating a crowded display as informative. The BDA's guide points the other way, towards white space and chunked information.[3]
FAQ
How big can a classroom display board be?
BB100 says boards with a surface spread of flame rating are permitted in classrooms but should not extend more than 2.5 m without a break of at least 0.4 m.[1]
Can I put display boards in a dead end corridor?
BB100 says not unless they are covered by a suitable material such as glass or polycarbonate.[1]
Does BB93 say anything about displays?
Only in passing: it lists ample surfaces for display materials among the other environmental needs a school design should consider.[2]
Related terms
- Notice board
- Felt notice board
- Working wall
- Visual timetable
- Dyslexia-friendly display
- Surface spread of flame
- Fire safety in schools (BB 100)
See it in our range
Notice boards for classrooms and corridors.
Sources
- Design for fire safety in schools: BB 100. Department for Education (GOV.UK), March 2014. Accessed November 2026.
- Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education (GOV.UK), February 2015. Accessed November 2026.