Building Bulletin 100 (BB 100) is the Department for Education's design guide for fire safety in schools in England and Wales, published in March 2014. It is largely based on Approved Document B, and includes limits on notice boards in classrooms and corridors.[1][2]
Key points
- BB 100 applies to nursery, primary and secondary schools, sixth form colleges, academies, city technology colleges, special schools and pupil referral units.[1]
- It is guidance. The bulletin says a designer is not required to follow it and may adopt an alternative approach, such as fire safety engineering.[1]
- Approved Document B names BB 100 as the document that covers the design of fire safety in schools.[3]
- It dates from March 2014, so its tables still show national classes that Approved Document B removed in 2025.[1][3]
How it works
BB 100 is aimed at designers, fire engineers, building control officers and fire safety officers, and it says head teachers, governors and facilities staff will also find it useful.[1] Its detailed sections, if followed, will usually enable a school design to satisfy requirements B1 to B5 of the Building Regulations.[1] It sits alongside the regulations as supporting technical guidance, and it also covers property protection, which it says can be more onerous than life safety measures.[1]
The numbers
Table 7 of BB 100 pairs national and European classes for wall and ceiling linings.[1]
- Small rooms of not more than 30 m2: national Class 3 or European D-s3, d2.[1]
- Other rooms: national Class 1 or European C-s3, d2.[1]
- Other circulation spaces: national Class 0 or European B-s3, d2.[1]
The bulletin notes that national classes do not automatically equate with European ones, so a product cannot usually assume a European class unless it was tested for it.[1] It also notes that Class 0 is not a classification identified in any British Standard test.[1] The national classes relied on tests in BS 476, and BSI lists BS 476-7:1997 as withdrawn on 4 March 2025.[4]
In schools and SEN settings
Special schools are within the scope of the bulletin, which does not set separate display rules for SEN settings.[1] Its notice board provisions apply generally.
- Section 5.2.2.1 permits notice boards with a surface spread of flame in classrooms, but they should not extend more than 2.5 m without a break of not less than 0.4 m, and should be away from potential sources of ignition.[1]
- Notice boards should not be provided in dead end corridors unless covered by a suitable material, for example glass or polycarbonate.[1]
- Section 3.1.6 says notice boards should not be more than 3 m wide, with a gap of at least 1 m between boards on the same wall, and boards in a protected corridor should be fitted with a cover, preferably top hung.[1]
How to choose
- Read the current Approved Document B alongside the bulletin, because the bulletin predates the 2025 amendments.[1][3]
- Ask the school's fire risk assessment or building control to confirm which display limits apply to the building.
- Ask suppliers for test evidence in the European system. See surface spread of flame.
What people get wrong
- Reading "Class 0" as a British Standard class. The bulletin itself says it is not.[1]
- Treating the bulletin as law. It describes itself as guidance a designer need not follow, and the Building Regulations are the requirement.[1]
- Assuming the 2014 text is current. Check the dated edition against the present Approved Document B.[3]
FAQ
Is Building Bulletin 100 still in use?
It remains published by the Department for Education, and Approved Document B still points to it for school fire safety design.[2][3] It is dated March 2014, so confirm with the school's fire risk assessor.[1]
Does it say how many notice boards a classroom can have?
It limits the run of boards rather than the count: no more than 2.5 m without a break of at least 0.4 m.[1]
Where do the Class 0 and Class 1 figures come from?
From Table 7, which gave them as national classes. See Class 0 fire rating and classroom display board.[1]
Related terms
- Approved Document B
- Classroom display board
- Surface spread of flame
- Notice board
- Class 0 fire rating
See it in our range
Notice boards: ask for the test evidence for the exact board and how it is fixed.
Sources
- Design for fire safety in schools: BB 100. Department for Education (GOV.UK), March 2014. Accessed November 2026.
- Design for fire safety in schools: BB 100 (publication page). Department for Education (GOV.UK), published 11 March 2014. Accessed November 2026.
- Approved Document B (fire safety) volume 2: Buildings other than dwellings, 2019 edition incorporating 2020, 2022, 2025 and 2026 amendments collated with 2029 amendments. Ministry of Housing, Communities and Local Government (GOV.UK), GOV.UK page last updated 16 September 2026. Accessed November 2026.
- BS 476-7:1997 Fire tests on building materials and structures: Method of test to determine the classification of the surface spread of flame of products. BSI Knowledge, published 15 January 1997, withdrawn 4 March 2025. Accessed November 2026.