Written by Joanne Mulloy, Acoustic Solutions Specialist & Technical Reviewer
Reviewed by Joe Sutcliffe, Managing Director & Lead Acoustic Surveyor
Presentation Spaces Ltd ·
Euroclass B is the third step in the European reaction to fire scale of BS EN 13501-1, below A1 and A2 and above C. A full rating adds a smoke mark (s1 to s3) and a droplet mark (d0 to d2), so B-s1, d0 and B-s3, d2 are different results.[1][2]
Key points
- Products other than floorings are classed A1, A2, B, C, D, E or F, with A1 the highest, and class F is given when a product fails to attain class E.[1]
- Classes A2 to E carry extra marks for smoke production (s1, s2, s3, with s1 the lowest) and flaming droplets or particles (d0, d1, d2, with d0 the lowest).[1]
- Approved Document B asks for B-s3, d2 in other circulation spaces, which sets no limit on smoke or droplets.[1]
- The standard is BS EN 13501-1:2018, listed by BSI as current.[2]
How it works
A product is tested to the European methods and then classified under BS EN 13501-1. Approved Document B explains that an untested product cannot be classified under the standard.[1] The BSI catalogue page confirms the 2018 edition, and BS EN 13501-1 itself is paywalled, so this page does not reproduce its test limits.[2]
The letter alone is not the whole result. A class of B-s1, d0 means a B class with the lowest smoke mark and the lowest droplet mark, while B-s3, d2 means a B class with no limit set on either.[1] A buyer comparing two boards should compare the full string and the substrate each was tested on, because Approved Document B notes that standard substrates are used to produce results representative of end uses.[1]
The numbers
- Small rooms of up to 30 m2 in non-residential accommodation: D-s3, d2, so Class B exceeds what the table asks for.[1]
- Other rooms: C-s3, d2.[1]
- Other circulation spaces, such as corridors: B-s3, d2.[1]
Building Bulletin 100, from March 2014, lists the same European classes in its Table 7 beside national classes, and warns that the national classes do not automatically equate with the European ones.[3]
In schools and SEN settings
For school corridors, Building Bulletin 100 pairs the old national Class 0 with European B-s3, d2.[3] The national test behind Class 1, BS 476-7:1997, is listed by BSI as withdrawn on 4 March 2025.[4] That makes the European class the evidence England's guidance now describes for linings.[1][4] Neither source says a school must buy a particular product; the school's fire risk assessment and building control decide.
How to choose
- Ask for the full class, such as B-s1, d0, and not only the letter.[1]
- Ask for the substrate and fixing method the class applies to.[1]
- Ask for the test report date, since a report quoting only a national class is older evidence.[1][4]
What people get wrong
- Equating Class 1 with Euroclass B. Building Bulletin 100 says national classes do not automatically equate with the European ones.[3]
- Reading B as the top class. Two classes, A1 and A2, sit above it.[1]
- Ignoring the s and d marks. They are part of the classification.[1]
FAQ
Is Euroclass B the same as Class 1?
No. BB 100 says products cannot typically assume a European class unless they were tested for it.[3]
Does Euroclass B mean a board will not burn?
No. It is a reaction to fire class: A1 and A2 sit above it, and C, D, E and F sit below it.[1]
Which standard defines it?
BS EN 13501-1:2018. See EN 13501-1 for the full scale.[2]
Related terms
- EN 13501-1
- Surface spread of flame
- Approved Document B
- Class 1 surface spread of flame
- Fire retardant notice board
See it in our range
Notice boards: ask for the full class, the substrate and the test report for the exact board.
Sources
- Approved Document B (fire safety) volume 2: Buildings other than dwellings, 2019 edition incorporating 2020, 2022, 2025 and 2026 amendments collated with 2029 amendments. Ministry of Housing, Communities and Local Government (GOV.UK), GOV.UK page last updated 16 September 2026. Accessed November 2026.
- BS EN 13501-1:2018 Fire classification of construction products and building elements: Classification using data from reaction to fire tests. BSI Knowledge, published 31 January 2019. Accessed November 2026.
- Design for fire safety in schools: BB 100. Department for Education (GOV.UK), March 2014. Accessed November 2026.
- BS 476-7:1997 Fire tests on building materials and structures: Method of test to determine the classification of the surface spread of flame of products. BSI Knowledge, published 15 January 1997, withdrawn 4 March 2025. Accessed November 2026.