Written by Joanne Mulloy, Acoustic Solutions Specialist & Technical Reviewer
Reviewed by Joe Sutcliffe, Managing Director & Lead Acoustic Surveyor
Presentation Spaces Ltd ·
The Regulatory Reform (Fire Safety) Order 2005 is the law in England and Wales that makes the responsible person for most non-domestic premises assess fire risks and take general fire precautions. It is separate from the Building Regulations, which govern building work and the guidance in Approved Document B.[1][2][3]
Key points
- The responsible person, for a workplace, is the employer if the workplace is to any extent under their control.[1]
- That person must take general fire precautions that ensure, so far as is reasonably practicable, the safety of employees, and take such precautions as may reasonably be required to make the premises safe for others.[2]
- The responsible person must make a suitable and sufficient assessment of the risks, review it regularly, and record its findings.[3]
- The Order does not apply to domestic premises, with exceptions, and the legislation.gov.uk text is marked as applying to England and Wales.[4]
How it works
Article 3 defines who carries the duty. For a workplace under their control it is the employer. For other premises it is the person in control in connection with a trade, business or other undertaking, whether or not for profit, or else the owner.[1]
Article 8 sets the duty to take general fire precautions. Article 9 then requires a risk assessment so that the responsible person can identify those precautions.[2][3] The assessment must be reviewed regularly, particularly if there is reason to suspect it is no longer valid or if there has been a significant change to the premises or how they are organised.[3] The responsible person must record the findings of the assessment and any group of people it identifies as especially at risk.[3]
How it relates to the Building Regulations
The Order sits beside the Building Regulations rather than inside them. The Building Regulations, and the approved document that supports them, deal with building work in England. Approved Document B itself notes that the Building Regulations do not impose requirements on the management of a building.[5] Management of fire safety in use is the territory of the Order.
How to choose
For display materials, the Order does not set a class or a test. It sets a duty to assess risk. That means the practical questions sit in the assessment.
- Ask who the responsible person is for the premises, and put any new display boards on the list the assessment covers.[3]
- Ask for the supplier's test evidence for the product, and check it against the guidance the assessor uses, such as Approved Document B or Building Bulletin 100 for schools.[5]
- Review the assessment when the layout changes, for example after boards are added to a corridor.[3]
What people get wrong
- Treating a product's fire rating as the same thing as compliance with the Order. The Order is about the assessment and the precautions that follow from it, and a rated product is one input.[3]
- Assuming it applies across the whole UK. The legislation.gov.uk text is marked for England and Wales, so check Scotland and Northern Ireland separately.[4]
- Assuming the Order names notice boards. The Order's articles read for this page set duties and say nothing about display materials.[2][3]
FAQ
Who is the responsible person in a school?
Article 3 gives the employer for a workplace under their control, and otherwise the person in control of the premises or the owner.[1] A school should confirm who holds the role in its own governance.
Does the Order set a fire rating for notice boards?
No. The articles read for this page contain no classes or test requirements.[2][3] Guidance on lining classes is in Approved Document B.
How often must the risk assessment be reviewed?
Regularly, and particularly if there is reason to suspect it is no longer valid or there has been a significant change.[3]
Related terms
See it in our range
Notice boards: put any board on the premises' fire risk assessment and ask for its test evidence.
Sources
- The Regulatory Reform (Fire Safety) Order 2005, article 3: Meaning of responsible person. legislation.gov.uk, SI 2005/1541, as shown on the site in November 2026. Accessed November 2026.
- The Regulatory Reform (Fire Safety) Order 2005, article 8: Duty to take general fire precautions. legislation.gov.uk, SI 2005/1541, as shown on the site in November 2026. Accessed November 2026.
- The Regulatory Reform (Fire Safety) Order 2005, article 9: Risk assessment. legislation.gov.uk, SI 2005/1541, as shown on the site in November 2026. Accessed November 2026.
- The Regulatory Reform (Fire Safety) Order 2005, article 6: Application to premises. legislation.gov.uk, SI 2005/1541, as shown on the site in November 2026. Accessed November 2026.
- Approved Document B (fire safety) volume 2: Buildings other than dwellings, 2019 edition incorporating 2020, 2022, 2025 and 2026 amendments collated with 2029 amendments. Ministry of Housing, Communities and Local Government (GOV.UK), GOV.UK page last updated 16 September 2026. Accessed November 2026.