Written by Joanne Mulloy, Acoustic Solutions Specialist & Technical Reviewer
Reviewed by Joe Sutcliffe, Managing Director & Lead Acoustic Surveyor
Presentation Spaces Ltd ·
EN 13501-1, published in the UK as BS EN 13501-1:2018, is the standard that classifies how construction products react to fire, using classes A1, A2, B, C, D, E and F, with A1 the best. Classes below A1 add smoke (s1 to s3) and flaming droplet (d0 to d2) ratings.[1][2]
Key points
- BS EN 13501-1:2018 is listed by BSI as current and supersedes the 2007 edition with its 2009 amendment, which is withdrawn.[1]
- A class such as B-s3, d2 has three parts: the main class, a smoke rating and a flaming droplet rating.[2]
- A classification is only valid for the substrate and end use it was tested on, so a certificate must match how the product is fixed.[2]
- Approved Document B, the fire safety guidance for England, now gives lining classes in this system only. The older BS 476 national classes were removed from it in 2025.[3][4]
How it works
A product is tested, then classified from the results. Approved Document B explains that reaction to fire is the degree to which a product contributes to a fire through its own decomposition, and that products other than floorings are classed A1, A2, B, C, D, E or F, with A1 the highest. Class F means the product failed to reach E, and an untested product cannot be classified at all.[2]
Classes A2 to E carry two extra marks. The smoke mark runs from s1, the lowest production, to s3. The droplet mark runs from d0, the lowest, to d2. A class that ends s3, d2 sets no limit on either.[2]
The numbers
Approved Document B volume 2 sets the lowest acceptable lining class by location in buildings other than dwellings.[2]
- Small rooms of up to 30 m2 in non-residential buildings: D-s3, d2.[2]
- Other rooms, including garages: C-s3, d2.[2]
- Other circulation spaces, such as corridors: B-s3, d2.[2]
Part of a wall may be worse than the table says, but no worse than D-s3, d2, as long as that area stays below half the floor area of the room and no more than 60 m2 in non-residential buildings.[2]
In schools and SEN settings
Approved Document B covers schools, colleges and offices among other buildings in England.[3] The word notice board does not appear in volume 2, so whether a particular board counts as a wall lining is a question for the building control body or the fire risk assessor, not something this page can settle. The DfE's fire safety guidance for schools, Building Bulletin 100, gives guidance on notice boards in corridors.[5] See surface spread of flame.
How to choose
- Ask for the full classification, including the s and d marks, and the substrate the board was tested on.[2]
- Check that the certificate covers the product as fixed, because small changes in fixing method or thickness can change the result.[2]
- Check the date. The old BS 476-7 test is withdrawn, so a certificate that quotes only a national class is no longer the evidence England's guidance describes.[3][4]
What people get wrong
- Treating Class 1 and Class B as the same thing. BB100 says the national classifications do not automatically equate with the European ones, so a product cannot usually assume a European class unless it was tested for it.[5]
- Quoting the letter without the substrate. A classification is only valid within its direct field of application.[2]
FAQ
Is EN 13501-1 the same as Euroclass?
Euroclass is the trade shorthand for the European classes. A board's class is written like B-s3, d2, and Euroclass B explains how to read one.[2]
Does EN 13501-1 apply in Scotland and Wales?
Approved Document B applies to England, so check the local building standards for Scotland, Wales and Northern Ireland separately.[3]
What replaced the national BS 476 classes?
Approved Document B removed national classes for reaction to fire in amendments that took effect on 2 March 2025, and BSI lists BS 476-7:1997 as withdrawn.[3][4] See BS 476 Part 7 and Class 1 surface spread of flame.
Related terms
- Euroclass B
- Surface spread of flame
- Approved Document B
- BS 476 Part 7
- Class 1 surface spread of flame
See it in our range
Notice boards, including Class B fire retardant felt boards: ask for the test evidence for the exact product and fixing before specifying it.
Sources
- BS EN 13501-1:2018 Fire classification of construction products and building elements: Classification using data from reaction to fire tests. BSI Knowledge, published 31 January 2019. Accessed November 2026.
- Approved Document B (fire safety) volume 2: Buildings other than dwellings, 2019 edition incorporating 2020, 2022, 2025 and 2026 amendments collated with 2029 amendments. Ministry of Housing, Communities and Local Government (GOV.UK), GOV.UK page last updated 16 September 2026. Accessed November 2026.
- Fire safety: Approved Document B. GOV.UK (Ministry of Housing, Communities and Local Government), last updated 16 September 2026. Accessed November 2026.
- BS 476-7:1997 Fire tests on building materials and structures: Method of test to determine the classification of the surface spread of flame of products. BSI Knowledge, published 15 January 1997, withdrawn 4 March 2025. Accessed November 2026.
- Design for fire safety in schools: BB 100. Department for Education (GOV.UK), March 2014. Accessed November 2026.