Written by Joanne Mulloy, Acoustic Solutions Specialist & Technical Reviewer
Reviewed by Joe Sutcliffe, Managing Director & Lead Acoustic Surveyor
Presentation Spaces Ltd ·
Building Bulletin 93 (BB93) is the Department for Education's guidance on acoustic performance standards for school buildings in England. It sets limits for indoor ambient noise, sound insulation and reverberation time, and describes the normal way to satisfy Requirement E4 of the Building Regulations and the School Premises Regulations.[1]
Key points
- BB93 is guidance, not legislation. The legal duties sit in the Building Regulations and the School Premises Regulations; BB93 describes the normal way of meeting them.[1]
- Every limit depends on the room type and on whether the work is new build or refurbishment.[1]
- Rooms for pupils with special hearing and communication needs have tighter limits.[1]
- The GOV.UK page for BB93 was last updated on 19 December 2014, so check GOV.UK for a newer version before quoting it.[2]
- This is a short entry. The full definition is at WorkSpace Acoustics.
How it works
BB93 section 1 sets the performance standards. Requirement E4 of the Building Regulations says each room in a school building must have the acoustic conditions and insulation against noise appropriate to its intended use, and the guidance supporting it points designers to the BB93 values.[1] The School Premises Regulations apply to both new and existing schools.[1]
The numbers
These are upper limits for rooms that are finished and furnished but unoccupied.[1]
- Primary or secondary classroom, indoor ambient noise: 35 dB new build and 40 dB refurbishment.[1]
- Primary classroom, reverberation time Tmf: 0.6 s new build and 0.8 s refurbishment.[1]
- Secondary classroom, reverberation time Tmf: 0.8 s new build and 1.0 s refurbishment.[1]
- Teaching space specifically for pupils with special hearing and communication needs, ambient noise: 30 dB new build and 35 dB refurbishment.[1]
- The same space, reverberation time: no more than 0.4 s averaged from 125 Hz to 4 kHz for new build, with no more than 0.6 s in any octave band, and 0.4 s for refurbishment.[1]
The 0.4 s figure applies only to rooms intended specifically for pupils with special hearing or communication needs.[1] A primary classroom is 0.6 s for new build.[1] The WorkSpace Acoustics entries on BB93 reverberation time limits and reverberation time cover the full tables.
Acoustic products and fire
BB93 section 0.6 notes that Requirement B2 of the Building Regulations controls the contribution surface linings make to fire growth. It says free hanging baffles are not part of the ceiling but should have the appropriate spread of flame classification, and that certificates of conformity are part of the Building Regulations approval process.[1] For the fire classes, see surface spread of flame and the DfE's fire guide, BB 100.[3]
In schools and SEN settings
BB93 says pupils with special educational needs are generally more sensitive to the acoustic environment, so reverberation times are shorter and ambient noise levels lower for them.[1] It lists hearing impairment, speech and language difficulties, ADHD, auditory processing disorder and autism among the needs of pupils who may have special hearing or communication needs.[1] See low-arousal classroom.
What people get wrong
- Treating BB93 as the law. It describes the normal way of satisfying the regulations.[1]
- Quoting one figure for every classroom. The limit changes with room type, and new build and refurbishment differ.[1]
- Expecting a certificate. BB93 section 2.3 describes pre-completion testing and reporting by a specialist acoustic consultant.[1]
FAQ
Is BB93 mandatory?
BB93 is guidance. The mandatory parts are Requirement E4 and the School Premises Regulations, and BB93 describes the normal means of meeting them.[1]
What is the BB93 reverberation limit for a primary classroom?
0.6 s for new build and 0.8 s for refurbishment, measured as Tmf.[1] See reverberation time.
Does BB93 say how much panel to fit?
This page found no coverage percentage in BB93. The limits are for reverberation time, not for panel area.[1] See acoustic panel.
Related terms
- Reverberation time
- Acoustic panel
- Ceiling raft
- Acoustic baffle
- Surface spread of flame
- Fire safety in schools (BB 100)
- Low-arousal classroom
See it in our range
Acoustic solutions, including panels, baffles and rafts.
Sources
- Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education (GOV.UK), February 2015. Accessed November 2026.
- Acoustic design of schools: performance standards: BB 93. GOV.UK (Department for Education), last updated 19 December 2014. Accessed November 2026.
- Design for fire safety in schools: BB 100. Department for Education (GOV.UK), March 2014. Accessed November 2026.